SolaX Power Network Technology (Zhejiang) Co.,Ltd.
SolaX Power Network Technology (Zhejiang) Co.,Ltd.
ENGLISH(GLOBAL)
x3 hyb g4 pro 1
x3 hyb g4 pro 2
x3 hyb g4 pro 3
Hybrid Inverter

X3 HYBRID G4 pro

G4 PRO

4kW / 5kW / 6kW / 8kW

10kW / 12kW / 15kW


Economically Efficient



  • 20A DC input per MPPT with 3 trackers

  • 200% PV oversizing and 110% AC overloading

  • Ultra-wide MPPT range of 110-950V


Flexible Expansion



  • Dual independent battery ports and 2-in-1 function for  effortless expansion

  • Additional ports for simplified wiring and installation

  • Functional and stylish wiring cover

  • Microgrid and generator modes for versatile operations


Safe and Reliable


  • Rapid shutdown function compatible

  • SPD-Ⅱ protection on both DC/AC sides, AFCI optional

  • 10s 200% EPS output with ≤10ms UPS level switch time


Smart Energy



  • V2X ready for smart home energy integration

  • Intuitive management with Smart Schedule, Scene,  and TOU

  • VPP ready, supporting FCAS, 2030.5, and OpenADR

  • Wireless meter compatible for convenient setup


Why X3 HYBRID G4 PRO

X3-HYB-G4 PRO offers flexible expansion with dual independent battery ports and versatile microgrid and generator modes. It ensures safety with rapid shutdown compatibility, SPD-II protection, and 10s 200% EPS output with fast UPS-level switch time. Smart energy management is enabled with V2X readiness, intuitive controls, and VPP compatibility. Economically, it supports 200% PV oversizing, 110% AC overloading, and features a 20A DC input per MPPT with 3 trackers, all within an ultra-wide MPPT range of 110-950V.


X3 HYD G4 PRO 4.0P
X3 HYD G4 PRO 5.0P
X3 HYD G4 PRO 6.0P
X3 HYD G4 PRO 8.0P
ParameterValue
Max. recommended PV array power [Wp]8000
Max. input voltage [V]1000
Nominal DC operating voltage [V]650
No. of MPP trackers / Strings per MPP tracker2 (1 / 1)
Max. input current (input 1 / input 2 / input 3) [A]PV1:20 / PV2:20
Max. short circuit current (input 1 / input 2 / input 3) [A]PV1:25 / PV2:25
MPPT operating voltage range [V]110-950
Start output voltage [V]140
Nominal AC power [VA]4000
Max. apparent AC power [VA]4400
Rated grid voltage (AC voltage range) [V]3P4W, 400 / 380
Rated grid frequency [Hz]50 / 60
Nominal AC current [A] (at 230V)5.8
Max. AC current [A]6.7
Displacement power factor~1 (Adjustable from 0.8 leading to 0.8 lagging)
Total harmonic distortion (THDi, rated power) [%]<3
Nominal AC power [VA]8000
Nominal AC current [A]11.6
Max. AC current [A]12.2


ParameterValue
Max. recommended PV array power [Wp]10000
Max. input voltage [V]1000
Nominal DC operating voltage [V]650
No. of MPP trackers / Strings per MPP tracker2 (1 / 1)
Max. input current (input 1 / input 2 / input 3) [A]PV1:20 / PV2:20
Max. short circuit current (input 1 / input 2 / input 3) [A]PV1:25 / PV2:25
MPPT operating voltage range [V]110-950
Start output voltage [V]140
Nominal AC power [VA]5000 (AS 4777 4999)
Max. apparent AC power [VA]5500 (AS 4777 4999)
Rated grid voltage (AC voltage range) [V]3P4W, 400 / 380
Rated grid frequency [Hz]50 / 60
Nominal AC current [A] (at 230V)7.2
Max. AC current [A]8.4
Displacement power factor~1 (Adjustable from 0.8 leading to 0.8 lagging)
Total harmonic distortion (THDi, rated power) [%]<3
Nominal AC power [VA]10000
Nominal AC current [A]14.5
Max. AC current [A]15.2


ParameterValue
Max. recommended PV array power [Wp]10000
Max. input voltage [V]1000
Nominal DC operating voltage [V]650
No. of MPP trackers / Strings per MPP tracker2 (1 / 1)
Max. input current (input 1 / input 2 / input 3) [A]PV1:20 / PV2:20
Max. short circuit current (input 1 / input 2 / input 3) [A]PV1:25 / PV2:25
MPPT operating voltage range [V]110-950
Start output voltage [V]140
Nominal AC power [VA]5000 (AS 4777 4999)
Max. apparent AC power [VA]5500 (AS 4777 4999)
Rated grid voltage (AC voltage range) [V]3P4W, 400 / 380
Rated grid frequency [Hz]50 / 60
Nominal AC current [A] (at 230V)7.2
Max. AC current [A]8.4
Displacement power factor~1 (Adjustable from 0.8 leading to 0.8 lagging)
Total harmonic distortion (THDi, rated power) [%]<3
Nominal AC power [VA]10000
Nominal AC current [A]14.5
Max. AC current [A]15.2


ParameterValue
Max. recommended PV array power [Wp]16000
Max. input voltage [V]1000
Nominal DC operating voltage [V]650
No. of MPP trackers / Strings per MPP tracker3 (1 / 1 / 1)
Max. input current (input 1 / input 2 / input 3) [A]PV1:20 / PV2:20 / PV3:20
Max. short circuit current (input 1 / input 2 / input 3) [A]PV1:25 / PV2:25 / PV3:25
MPPT operating voltage range [V]110-950
Start output voltage [V]140
Nominal AC power [VA]8000
Max. apparent AC power [VA]8800
Rated grid voltage (AC voltage range) [V]3P4W, 400 / 380
Rated grid frequency [Hz]50 / 60
Nominal AC current [A] (at 230V)11.6
Max. AC current [A]13.4
Displacement power factor~1 (Adjustable from 0.8 leading to 0.8 lagging)
Total harmonic distortion (THDi, rated power) [%]<3
Nominal AC power [VA]16000
Nominal AC current [A]23.2
Max. AC current [A]24.3



Related Products
DataHub 1000 DataHub 1000
DataHub 1000
Intelligent Export Control
Pocket Dongle Pocket Dongle
Pocket Dongle
SolaX Cloud Monitoring
Meter Meter
Meter
Smart Monitoring
Documents
Datasheet
English
Language
English
Format
PDF
Size
333KB
Last updated
22/11/2024
Feedback
SolaX Power Network Technology (Zhejiang) Co.,Ltd.
We use cookies to optimise and personalise your experience, but you can choose to opt out of non-essential cookies.
To find out more, read our Privacy Policy and Terms of Use
Reject All
Accept All