800W/ 900W / 1000W / 1200W
Support micro-grid solution
Support AC coupling solution
Support 1-phase microinverter integration into 3-phase power grids
Max. 1200VA output power
Max. 20A DC input current
Two MPPT channels, small size, light weight
Built-in industrial grade Wi-Fi module
Safety protection relay integrated
IP67 protection class
Reactive power control
Rapid shutdown function
Easy to install and maintain
Experience the next generation of solar energy with the SolaX X1 Micro Inverter 2 in 1. Designed for residential and small-scale commercial applications, this compact and lightweight inverter offers a maximum output of 1200VA and 20A DC input current, ensuring efficient energy conversion. With two MPPT channels, it optimizes performance from your solar panels. The SolaX X1Micro Inverter 2 in 1 is not just efficient; it's safe, featuring an IP67 rating and a built-in industrial-grade Wi-Fi module for seamless connectivity. Its intelligent design includes reactive power control and a rapid shutdown function, making it easy to install and maintain. Plus, with flexible adaptability to support micro-grids, AC coupling, and integration into 3-phase power grids, the X1 Micro Inverter is the smart choice for your solar power needs.
DC INPUT | |
Specification | 240 ~ 470+ W |
Max. PV input voltage | 60 V |
MPPT voltage range | 22 ~ 60 V |
Start-up voltage | 22 V |
Max. PV input current | 2 ×15 A |
Max. input short circuit current Isc | 2 × 20 A |
No. of MPPT trackers | 2 |
Strings per MPPT tracker | 1 |
AC OUTPUT | |
Specification | 750 VA |
Maximum continuous output power | 750 VA |
Maximum continuous output current | 3.41 A @220 V |
3.26 A @230 V | |
3.13 A @240 V | |
Rated grid voltage/range | 1 / N / PE, 220/230/240 V |
Nominal AC voltage range | 180 ~ 264 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency / range | 50 卤 5 Hz / 60 卤 5 Hz |
Maximum units per 10AWG branch* | 8 @220 V |
8 @230 V | |
8 @240 V | |
Maximum units per 12AWG branch* | 6 @220 V |
6 @230 V | |
6 @240 V | |
Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (Rated power) | < 3% |
EFFICIENCY | |
Max. efficiency | 96.50% |
Nominal MPPT efficiency | 99.50% |
Night power consumption | < 40 mW |
DC INPUT | |
Specification | 320 ~ 540+ W |
Max. PV input voltage | 60 V |
MPPT voltage range | 22 ~ 60 V |
Start-up voltage | 22 V |
Max. PV input current | 2 × 16 A |
Max. input short circuit current Isc | 2 × 25 A |
No. of MPPT trackers | 2 |
Strings per MPPT tracker | 1 |
AC OUTPUT | |
Specification | 800 VA |
Maximum continuous output power | 800 VA |
Maximum continuous output current | 3.64 A @220 V |
3.48 A @230 V | |
3.34 A @240 V | |
Rated grid voltage/range | |
Nominal AC voltage range | 180 ~ 264 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency / range | |
Maximum units per 10AWG branch* | 7 @220 V |
8 @230 V | |
8 @240 V | |
Maximum units per 12AWG branch* | 5 @220 V |
6 @230 V | |
6 @240 V | |
Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (Rated power) | < 3% |
EFFICIENCY | |
Max. efficiency | 96.50% |
Nominal MPPT efficiency | 99.50% |
Night power consumption | < 40 mW |
DC INPUT | |
Specification | 360 ~ 600+ W |
Max. PV input voltage | 60 V |
MPPT voltage range | 22 ~ 60 V |
Start-up voltage | 22 V |
Max. PV input current | 2 脳 16 A |
Max. input short circuit current Isc | 2 脳 25 A |
No. of MPPT trackers | 2 |
Strings per MPPT tracker | 1 |
AC OUTPUT | |
Specification | 900 VA |
Maximum continuous output power | 900 VA |
Maximum continuous output current | 4.10 A @220 V |
3.92 A @230 V | |
3.75 A @240 V | |
Rated grid voltage/range | |
Nominal AC voltage range | 180 ~ 264 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency / range | |
Maximum units per 10AWG branch* | 6 @220 V |
7 @230 V | |
7 @240 V | |
Maximum units per 12AWG branch* | 5 @220 V |
5 @230 V | |
5 @240 V | |
Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (Rated power) | < 3% |
EFFICIENCY | |
Max. efficiency | 96.50% |
Nominal MPPT efficiency | 99.50% |
Night power consumption | < 40 mW |
DC INPUT | |
Specification | 360 ~ 600+ W |
Max. PV input voltage | 60 V |
MPPT voltage range | 22 ~ 60 V |
Start-up voltage | 22 V |
Max. PV input current | 2 × 20 A |
Max. input short circuit current Isc | 2 × 25 A |
No. of MPPT trackers | 2 |
Strings per MPPT tracker | 1 |
AC OUTPUT | |
Specification | 1000 VA |
Maximum continuous output power | 1000 VA |
Maximum continuous output current | 4.55 A @220 V |
4.35 A @230 V | |
4.17 A @240 V | |
Rated grid voltage/range | |
Nominal AC voltage range | 180 ~ 264 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency / range | |
Maximum units per 10AWG branch* | 6 @220 V |
6 @230 V | |
6 @240 V | |
Maximum units per 12AWG branch* | 4 @220 V |
5 @230 V | |
5 @240 V | |
Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (Rated power) | < 3% |
EFFICIENCY | |
Max. efficiency | 96.50% |
Nominal MPPT efficiency | 99.50% |
Night power consumption | < 40 mW |
DC INPUT | |
Specification | 400 ~ 670+ W |
Max. PV input voltage | 60 V |
MPPT voltage range | 22 ~ 60 V |
Start-up voltage | 22 V |
Max. PV input current | 2 × 20 A |
Max. input short circuit current Isc | 2 × 25 A |
No. of MPPT trackers | 2 |
Strings per MPPT tracker | 1 |
AC OUTPUT | |
Specification | 1200 VA |
Maximum continuous output power | 1200 VA |
Maximum continuous output current | 5.46 A @220 V |
5.22 A @230 V | |
4.73 A @240 V | |
Rated grid voltage/range | |
Nominal AC voltage range | 180 ~ 264 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency / range | |
Maximum units per 10AWG branch* | 5 @220 V |
5 @230 V | |
5 @240 V | |
Maximum units per 12AWG branch* | 3 @220 V |
4 @230 V | |
4 @240 V | |
Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (Rated power) | < 3% |
EFFICIENCY | |
Max. efficiency | 96.50% |
Nominal MPPT efficiency | 99.50% |
Night power consumption | < 40 mW |